you need
  • - water leakage monitoring system with a scheme of its installation;
  • - project of placing the main components of the system;
  • - corrugated pipe;
  • - punch;
  • - wire cutters;
  • - knife.
Guide
1
Make the layout of the main unit, sensors and solenoid valves taking into account the length of the connecting wires.
2
Guided accompanying diagram, make a gasket assembling wires, and then follow the sidebar of the solenoid valve.
3
Install water sensor.This can be done in two ways.The first method: Place the sensor water leakage in the floor covering (this will have to make a small hole in the tile or other floor coverings and install there the controller).Sensor Installation of water on the floor
- a sensible decision, because that is where the water begins to accumulate in the case of an emergency rush.Water sensor mounted contact plates up and so that the controller has performed over the line on the floor 3-4 mm: this prevents false alarms.A suitable place for the sensor wire in the corrugated pipe.Second method: Place the sensor on the floor (with the contact plate must be placed down), and the connecting wire let it lie on the floor.
4
Install control unit.The location you choose to install the control unit on the wall, drill two holes (one for the control itself and the second suitable for the power supply wires to it).Prepare special channels in the wall of a wiring connecting the control unit with each sensor and the water solenoid valve.Then set in the wall terminal boxes, and then perform the installation of the control unit.
5
Connect system: water sensors and solenoid valves connect to the control unit.For this purpose, the wires from the sensor water leakage, cut in the right places, then smooth out and connect them to the wires connected to the terminal pins of the control unit.When the solenoid valve is connected to the control system, make sure that the valve is grounded.At the very least, connect the power cord to the control unit.